PRODUCTS
Product Details
0.6/1kV XLPE Insulated Power Cables
1. Main Application
XLPE(Cross linked polyethylene) cable constitutes the best cable for transmission and distribution lines because of its excellent electrical and physical properties. These cables has the advantage of simplicity in construction, lightness in weight; convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route.
2. Standards
GB/12706-2008, IEC60502,IEC 60228,IEC60332 BS 5467,BS 6622 , IS 1554 , IS 7098and ICEA S-66-524 ect.
*KAIQI POWER can also design and produce for special application requirement.
3. Product Properties
The product is suitable for power transmission and distribution lines with rated power frequency voltage 0.6/1 kV .
3.1 Rated voltages: 0.6/1 kV
3.2 The ambient temperature for installation: ≥0℃
3.3 Maximum conductor temperature in normal operation:≤90℃
3.4 Max operating temperature of con. When cable short-circuited(5s maximum duration): 250℃
3.5 Permissible minimum bending radius:
Single unarmoured cable: (20D±5%)mm
Multi-core unarmoured cable:(15D±5%)mm
Single armoured cable: (15D±5%)mm
Multi-core armoured cable:(12D±5%)mm
Note : D=over cable diameter
4. Product Type
Chinese Type |
Description |
Application |
|
Cu |
Al |
||
YJV |
YJLV |
Cu conductor(Al conductor)XLPE insulated PVC sheathed power cable |
Laying indoors, in tunnel, fixed on the bracket, pipe and buried in the soil, the cable can not bear external mechanical forces. |
YJY |
YJLY |
Cu conductor(Al conductor)XLPE insulated PE sheathed power cable |
|
YJV22 |
YJLV22 |
Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PVC sheathed power cable |
For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
YJV23 |
YJLV23 |
Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PE sheathed power cable |
|
YJV62 |
YJLV62 |
Cu conductor(Al conductor)XLPE insulated double of aluminium-tape armored PVC sheathed power cable |
|
YJV32 |
YJLV32 |
Cu conductor(Al conductor)XLPE insulated steel-wire armored PVC sheathed power cable |
For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force |
YJV33 |
YJLV33 |
Cu conductor(Al conductor)XLPE insulated steel-wire armored PE sheathed power cable |
|
YJV72 |
YJLV72 |
Cu conductor(Al conductor)XLPE insulated aluminium-wire armored PE sheathed power cable |
1. Main Application
XLPE(Cross linked polyethylene) cable constitutes the best cable for transmission and distribution lines because of its excellent electrical and physical properties. These cables has the advantage of simplicity in construction, lightness in weight; convenience in application besides its excellent electrical, thermal, mechanical and anti-chemical corrosion properties. It can also be laid with no limitation of level difference along the route.
2. Standards
GB/12706-2008, IEC60502,IEC 60228,IEC60332 BS 5467,BS 6622 , IS 1554 , IS 7098and ICEA S-66-524 ect.
*KAIQI POWER can also design and produce for special application requirement.
3. Product Properties
The product is suitable for power transmission and distribution lines with rated power frequency voltage 0.6/1 kV .
3.1 Rated voltages: 0.6/1 kV
3.2 The ambient temperature for installation: ≥0℃
3.3 Maximum conductor temperature in normal operation:≤90℃
3.4 Max operating temperature of con. When cable short-circuited(5s maximum duration): 250℃
3.5 Permissible minimum bending radius:
Single unarmoured cable: (20D±5%)mm
Multi-core unarmoured cable:(15D±5%)mm
Single armoured cable: (15D±5%)mm
Multi-core armoured cable:(12D±5%)mm
Note : D=over cable diameter
4. Product Type
Type |
Specification |
Outer diameter of conductor |
Nominal thickness of insulation |
Nominal sheath thickness |
Approx.outer diameter of cable |
Approx. Weight of cable |
Ampacity of cable |
||||
Air |
Soil |
||||||||||
CU |
AL |
Cu |
Al |
Cu |
Al |
||||||
YJV YJLV |
mm2 |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
A |
A |
A |
A |
1×4 RE |
2.24 |
0.7 |
1.4 |
6.5 |
73.7 |
49.0 |
45 |
35 |
60 |
50 |
|
1×6 RE |
2.76 |
0.7 |
1.4 |
7.0 |
95.8 |
58.7 |
55 |
45 |
70 |
50 |
|
1×10 CC |
3.8 |
0.7 |
1.4 |
8.0 |
140.1 |
78.2 |
75 |
60 |
95 |
75 |
|
1×16 CC |
4.8 |
0.7 |
1.4 |
9.0 |
201.8 |
102.8 |
100 |
80 |
125 |
100 |
|
1×25 CC |
6.0 |
0.9 |
1.4 |
10.6 |
298.9 |
144.2 |
140 |
115 |
160 |
130 |
|
1×35 CC |
7.0 |
0.9 |
1.4 |
11.6 |
396.7 |
180.2 |
175 |
140 |
190 |
150 |
|
1×50 CC |
8.4 |
1.0 |
1.4 |
13.1 |
543.9 |
234.6 |
210 |
170 |
225 |
180 |
|
1×70 CC |
10.0 |
1.1 |
1.4 |
15.0 |
744.7 |
311.6 |
270 |
215 |
280 |
225 |
|
1×95 CC |
11.5 |
1.1 |
1.5 |
16.6 |
985.6 |
397.8 |
340 |
275 |
335 |
270 |
|
1×120 CC |
13.0 |
1.2 |
1.5 |
18.4 |
1233.0 |
490.6 |
400 |
320 |
380 |
305 |
|
1×150 CC |
14.5 |
1.4 |
1.6 |
20.5 |
1533.8 |
605.8 |
460 |
370 |
425 |
340 |
|
1×185 CC |
16.2 |
1.6 |
1.6 |
22.7 |
1884.9 |
740.3 |
530 |
415 |
480 |
375 |
|
1×240 CC |
18.4 |
1.7 |
1.7 |
25.3 |
2418.0 |
933.1 |
625 |
490 |
555 |
435 |
|
1×300 CC |
20.5 |
1.8 |
1.8 |
27.7 |
2996.5 |
1140.4 |
720 |
565 |
630 |
495 |
|
1×400 CC |
23.5 |
2.0 |
1.9 |
31.4 |
3962.3 |
1487.5 |
815 |
640 |
705 |
555 |
|
1×500 CC |
26.5 |
2.2 |
2.0 |
35.0 |
4933.0 |
1839.5 |
855 |
680 |
765 |
595 |
|
1×630 CC |
30.0 |
2.4 |
2.2 |
39.1 |
6188.8 |
2291.0 |
980 |
790 |
860 |
680 |
Note:RE=circular solid,CC=compacted circular stranded,SM=sector shaped stranded
Copyright(2014-2017)Henan Kaiqi Power Industry Co.,Ltd . 豫ICP备14006067号
Newport Road West,Airport District,Zhengzhou,Henan,China.P.C.451162 Tel:+86 371 5566 8386 Fax:+86 371 5536 0157 Email:frank@kaiqicable.com