All Aluminum Conductor (AAC) Cables

Retail price
0.0
Yuan
Market price
0.0
Yuan
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Category
1
DESCRIPTION
Parameters

  1. Application

  AAC are a refined Aluminium stranded conductor with a minimum metal purity of 99.7%. It is principally used in urban areas where spacing is short and the supports are close. It can be used in coastal regions owing to its high degree of corrosion resistance and is also used extensively within the Railway and Metro industries.

  2. Standards

  Basic design to BS 215-1 / BS EN 50182 / IEC 61089 / ASTM B 231/B 231M / DIN 48201-5 standards

  3. Cable Construction

  Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands

  of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized. All aluminium conductors are made up of one or more strands of aluminium wire dep.

  4. Electrical Properties

Density@20ºC

2.703 kg/dm

Temperature Coefficient@20°C

0.00403 (°C)

Resistivity@20°C

0.028264

Linear Expansivity

23 x10-6 (°C)

  5. Service Conditions

Ambient Temperature

-5°C - 50°C

Wind Pressure

80 – 130kg/m2

Seismic Acceleration

0.12 - 0.05g

Isokeraunic Level

10 – 18

Relative Humidity

5 – 100%

Density@20ºC

2.703 kg/dm

Temperature Coefficient@20°C

0.00403 (°C)

Resistivity@20°C

0.028264

Linear Expansivity

23 x10-6 (°C)

  6. All Aluminum Conductors (AAC) IEC 61089 Standard

Code 

Nominal cross-sectional area

Number of strands

 

 Diameter 

Approximate weight of cable 

Nominal 
Breaking Load 

Maximum DC 
Resistance at 20

Single wire

 Conductor

mm2

mm 

mm 

kg/km 

kN 

Ω/km

10 

10 

1.35 

4.05 

27.4 

1.95 

2.8633 

16 

16 

1.71 

5.12 

43.8 

3.04 

1.7896 

25 

25 

2.13 

6.40 

68.4 

4.50 

1.1453 

40 

40 

2.70 

8.09 

109.4 

6.80 

0.7158 

63 

63 

3.39 

10.2 

172.3 

10.39 

0.4545 

100 

100 

19 

2.59 

12.9 

274.8 

17.00 

0.2877 

125 

125 

19 

2.89 

14.5 

343.6 

21.25 

0.2302 

160 

160 

19 

3.27 

16.4 

439.8 

26.40 

0.1798 

200 

200 

19 

3.66 

18.3 

549.7 

32.00 

0.1439 

250 

250 

19 

4.09 

20.5 

687.1 

40.00 

0.1151 

315 

315 

37 

3.29 

23.0 

867.9 

51.97 

0.0916 

400 

400 

37 

3.71 

26.0 

1102.0 

64.00 

0.0721 

450 

450 

37 

3.94 

27.5 

1239.8 

72.00 

0.0641 

600 

600 

37 

4.15 

29.0 

1377.6 

80.00 

0.0577 

560 

560 

37 

4.39 

30.7 

1542.9 

89.60 

0.0515 

630 

630 

61 

3.63 

32.6 

1738.3 

100.80 

0.0458 

710 

710 

61 

3.85 

34.6 

1959.1 

113.60 

0.0407 

800 

800 

61 

4.09 

36.8 

2207.4 

128.00 

0.0361 

900 

900 

61 

4.33 

39.0 

2483.3 

144.00 

0.0321 

1000 

1000 

61 

4.57 

41.1 

2759.2 

160.00 

0.0289 

1120 

1120 

91 

3.96 

43.5 

3093.5 

179.20 

0.0258 

1250 

1250 

91 

4.18 

46.0 

3452.6 

200.00 

0.0231 

1400 

1400 

91 

4.43 

48.7 

3866.9 

224.00 

0.0207 

1500

1500 

91 

4.58 

50.4 

4143.1 

240.00 

0.0193 

 